Optimum design of a stand-alone hybrid power system with demand-side management.

Show simple item record

dc.contributor.author Michael, M. B.
dc.contributor.author Acakpovi, A.
dc.date.accessioned 2023-01-18T13:20:25Z
dc.date.available 2023-01-18T13:20:25Z
dc.date.issued 2017
dc.identifier.other 10.1016/j.promfg.2016.12.093
dc.identifier.uri https://www.sciencedirect.com/science/article/pii/S2351978916302566
dc.identifier.uri http://atuspace.atu.edu.gh:8080/handle/123456789/2416
dc.description.abstract Hybridising renewable energy sources improves the reliability of renewable energy systems for stand-alone applications. However, the high system cost is one of the setbacks that contribute to the slow growth of renewable energy development. The system cost can be reduced by optimal system design. This paper presents hybrid system design strategies that minimize the system capital cost. The design concept considers integration of demand-side management (DSM) strategy in the system design process. In this strategy, the residential load is divided into three categories and prioritized two of them. This reduces the peak load, in effect reduces the system design capacity. A traditional design method was used to design a hybrid system to meet a specific daily load profile of a typical 3-bedroom residential facility in Tema, Ghana. The system capacity, system capital cost, net present cost, capacity shortage and excess generation of the system were considered as hypothesis. The algorithm of the proposed design strategy was used to design an optimal system for the same daily load profile. Upon comparison of the two systems, the following observations were made; the system capacity reduced from 8.4 kW to 4.3 kW, the initial cost and the net present cost of the optimal system reduced by 48% and 41.5% respectively, system capacity shortage was slightly improved from 9.5% to 8.8%. The costs of energy (COE) improved from 0.793 kWh to 0.742 kWh, 6.4% reduction. The resualmost half which significantly reduced the system initial cost by 41.5 percent.lts indicate that, the proposed design method reduces the system capacity by en_US
dc.language.iso en_US en_US
dc.publisher Procedia Manufacturing en_US
dc.relation.ispartofseries vol;7
dc.subject Design method en_US
dc.subject Demand-side Management en_US
dc.subject Hybrid system en_US
dc.title Optimum design of a stand-alone hybrid power system with demand-side management. en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account